Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Sci Rep ; 12(1): 2843, 2022 02 18.
Artigo em Inglês | MEDLINE | ID: covidwho-1701343

RESUMO

In the context of social events reopening and economic relaunch, sanitary surveillance of SARS-CoV-2 infection is still required. Here, we evaluated the diagnostic performances of a rapid, extraction-free and connected reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assay on saliva. Nasopharyngeal (NP) swabs and saliva from 443 outpatients were collected simultaneously and tested by reverse-transcription quantitative PCR (RT-qPCR) as reference standard test. Seventy-one individuals (16.0%) were positive by NP and/or salivary RT-qPCR. Sensitivity and specificity of salivary RT-LAMP were 85.9% (95%CI 77.8-94.0%) and 99.5% (98.7-100%), respectively. Performances were similar for symptomatic and asymptomatic participants. Moreover, SARS-CoV-2 genetic variants were analyzed and no dominant mutation in RT-LAMP primer region was observed during the period of the study. We demonstrated that this RT-LAMP test on self-collected saliva is reliable for SARS-CoV-2 detection. This simple connected test with optional automatic results transfer to health authorities is unique and opens the way to secure professional and social events in actual context of economics restart.


Assuntos
Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , SARS-CoV-2/isolamento & purificação , Saliva/virologia , Adulto , Infecções Assintomáticas , Feminino , Humanos , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Carga Viral , Adulto Jovem
2.
J Clin Lab Anal ; 36(2): e24226, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: covidwho-1611241

RESUMO

INTRODUCTION: RT-PCR is widely used as a diagnostic test for the detection of SARS-CoV-2. In this study, we aim to describe the clinical utility of serial PCR testing in the final detection of COVID-19. METHOD: We collected multiple nasopharyngeal swab samples from patients who had negative RT-PCR test on the first day after hospitalization. RT-PCR tests were performed on the second day for all patients with initial negative result. For the patients with secondary negative results on day 2, tertiary RT-PCR tests were performed on day 3 after hospitalization. RESULT: Among 68 patients with initial negative test results, at the end of follow-up, the mortality number was 20 (29.4%). About 33.8% of patients had subsequent positive PCR test results for the second time and 17.4% of the patients who performed third PCR test had positive result. CONCLUSION: Based on this study, serial RT-PCR testing is unlikely to yield additional information.


Assuntos
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/genética , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/normas , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Reação em Cadeia da Polimerase em Tempo Real/estatística & dados numéricos , SARS-CoV-2/isolamento & purificação
3.
Ann Glob Health ; 87(1): 71, 2021.
Artigo em Inglês | MEDLINE | ID: covidwho-1332318

RESUMO

Despite the pandemic, 34,154 migrants, refugees or asylum-seekers landed in Sicily (Italy) in 2020, representing the main point of entry by sea into Europe. The SARS-CoV-2 surveillance program among migrants arriving to Sicily via the Mediterranean Sea, made by the combination of clinical examination and molecular testing, has been integrated by full-genome sequencing strains using the NGS technology from the last week of February. To date, more than one hundred full-genome strains have been sequenced and 8 different lineages have been identified mostly belonging to the lineages B.1.1.7 and B.1.525. As global access to COVID-19 vaccines should be ensured, the need to provide more detailed information to inform policies and to drive the possible re-engineering of vaccines needed to deal with the challenge of new and future variants should be highlighted.


Assuntos
COVID-19 , Genoma Viral , SARS-CoV-2 , Migrantes/estatística & dados numéricos , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/classificação , Vacinas contra COVID-19/normas , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Sicília/epidemiologia
4.
Virol J ; 18(1): 13, 2021 01 09.
Artigo em Inglês | MEDLINE | ID: covidwho-1067245

RESUMO

BACKGROUND: COVID-19 is diagnosed via detection of SARS-CoV-2 RNA using real time reverse-transcriptase polymerase chain reaction (rtRT-PCR). Performance of many SARS-CoV-2 rtRT-PCR assays is not entirely known due to the lack of a gold standard. We sought to evaluate the false negative rate (FNR) and sensitivity of our laboratory-developed SARS-CoV-2 rtRT-PCR targeting the envelope (E) and RNA-dependent RNA-polymerase (RdRp) genes. METHODS: SARS-CoV-2 rtRT-PCR results at the Public Health Laboratory (Alberta, Canada) from January 21 to April 18, 2020 were reviewed to identify patients with an initial negative rtRT-PCR followed by a positive result on repeat testing within 14 days (defined as discordant results). Negative samples from these discordant specimens were re-tested using three alternate rtRT-PCR assays (targeting the E gene and N1/N2 regions of the nucleocapsid genes) to assess for false negative (FN) results. RESULTS: During the time period specified, 95,919 patients (100,001 samples) were tested for SARS-CoV-2. Of these, 49 patients were found to have discordant results including 49 positive and 52 negative swabs. Repeat testing of 52 negative swabs found five FNs (from five separate patients). Assuming 100% specificity of the diagnostic assay, the FNR and sensitivity in this group of patients with discordant testing was 9.3% (95% CI 1.5-17.0%) and 90.7% (95% CI 82.6-98.9%) respectively. CONCLUSIONS: Studies to understand the FNR of routinely used assays are important to confirm adequate clinical performance. In this study, most FN results were due to low amounts of SARS-CoV-2 virus concentrations in patients with multiple specimens collected during different stages of infection. Post-test clinical evaluation of each patient is advised to ensure that rtRT-PCR results are not the only factor in excluding COVID-19.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2/isolamento & purificação , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Canadá , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Sensibilidade e Especificidade
5.
Biosens Bioelectron ; 178: 113049, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: covidwho-1056383

RESUMO

Prompt diagnosis, patient isolation, and contact tracing are key measures to contain the coronavirus disease 2019 (COVID-19). Molecular tests are the current gold standard for COVID-19 detection, but are carried out at central laboratories, delaying treatment and control decisions. Here we describe a portable assay system for rapid, onsite COVID-19 diagnosis. Termed CODA (CRISPR Optical Detection of Anisotropy), the method combined isothermal nucleic acid amplification, activation of CRISPR/Cas12a, and signal generation in a single assay, eliminating extra manual steps. Importantly, signal detection was based on the ratiometric measurement of fluorescent anisotropy, which allowed CODA to achieve a high signal-to-noise ratio. For point-of-care operation, we built a compact, standalone CODA device integrating optoelectronics, an embedded heater, and a microcontroller for data processing. The developed system completed SARS-CoV-2 RNA detection within 20 min of sample loading; the limit of detection reached 3 copy/µL. When applied to clinical samples (10 confirmed COVID-19 patients; 10 controls), the rapid CODA test accurately classified COVID-19 status, in concordance with gold-standard clinical diagnostics.


Assuntos
Técnicas Biossensoriais/métodos , Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Polarização de Fluorescência/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/estatística & dados numéricos , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Sistemas CRISPR-Cas , Desenho de Equipamento , Polarização de Fluorescência/instrumentação , Polarização de Fluorescência/estatística & dados numéricos , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
6.
Biosens Bioelectron ; 178: 113041, 2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: covidwho-1051492

RESUMO

The outbreak of COVID-19 caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been challenging human health worldwide. Loop-mediated isothermal amplification (LAMP) has been promptly applied to the detection of SARS-CoV-2 owing to its high amplification efficacy and less requirement of the thermal cycler. However, the vast majority of these LAMP-based assays depend on the non-specific detection of LAMP products, which can not discern the undesirable amplificons, likely to yield unreliable results. Herein, a sequence-specific LAMP assay was reported to detect SARS-CoV-2 using proofreading enzyme-mediated probe cleavage (named Proofman), which could realize real-time and visual detection without uncapping. This assay, introducing a proofreading enzyme and the fluorogenic probe to reverse-transcription LAMP (RT-Proofman-LAMP), can specifically detect the SARS-CoV-2 RNA with a detection limit of 100 copies. In addition to the real-time analysis, the assay is capable of endpoint visualization under a transilluminator within 50 min, providing a convenient reporting manner under the setting of point-of-care testing (POCT). In combination with different fluorophores, the one-pot multiplex assay was successfully achieved to detect multiple targets of SARS-CoV-2 and inner control simultaneously. In summary, the development of RT-Proofman-LAMP offers a versatile and highly-specific method for fast field screening and laboratory testing of SARS-CoV-2, making it a promising platform in COVID-19 diagnosis.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , COVID-19/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/estatística & dados numéricos , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Reação em Cadeia da Polimerase Multiplex/métodos , Reação em Cadeia da Polimerase Multiplex/estatística & dados numéricos , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Pandemias , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , RNA Viral/análise , RNA Viral/genética , Sensibilidade e Especificidade
7.
Biosens Bioelectron ; 172: 112766, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: covidwho-893625

RESUMO

The 2019 novel coronavirus disease (COVID-19) pandemic caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has affected all aspects of human life. Rapid, accurate, sensitive and user friendly detection method is urgently needed to facilitate early intervention and control the spread of SARS-CoV-2. Here, we propose a one-pot visual SARS-CoV-2 detection system named "opvCRISPR" by integrating reverse transcription loop-mediated isothermal amplification (RT-LAMP) and Cas12a cleavage in a single reaction system. We demonstrate that the collateral activity against single-stranded DNA (ssDNA) reporters of activated Cas12a triggered by RT-LAMP amplicon increases detection sensitivity and makes detection results observable with naked eye. The opvCRISPR enables detection at nearly single molecule level in 45 min. We validate this method with 50 SARS-CoV-2 potentially infected clinical samples. The opvCRISPR diagnostic results provide 100% agreement with the Centers for Disease Control and Prevention (CDC)-approved quantitative RT-PCR assay. The opvCRISPR holds great potential for SARS-CoV-2 detection in next-generation point-of-care molecular diagnostics.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Sistemas CRISPR-Cas , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , SARS-CoV-2/genética , Sequência de Bases , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/instrumentação , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Humanos , Técnicas de Diagnóstico Molecular/instrumentação , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Pandemias , RNA Viral/genética , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
8.
Biomed Res Int ; 2020: 8397053, 2020.
Artigo em Inglês | MEDLINE | ID: covidwho-841506

RESUMO

INTRODUCTION: The Portuguese healthcare system had to adapt at short notice to the COVID-19 pandemic. We implemented workflow changes to our molecular pathology laboratory, a national reference center, to maximize safety and productivity. We assess the impact this situation had on our caseload and what conclusions can be drawn about the wider impact of the pandemic in oncological therapy in Portugal. Material and Methods. We reviewed our database for all oncological molecular tests requested between March and April of 2019 and 2020. For each case, we recorded age, sex, region of the country, requesting institution, sample type, testing method, and turnaround time (TAT). A comparison between years was made. RESULTS: The total number of tests decreased from 421 in 2019 to 319 in 2020 (p = 0.0027). The greatest reduction was in clinical trial-related cases. Routine cases were similar between years (267 vs. 256). TAT was higher in 2019 (mean 15 days vs. 12.3 days; p = 0.0003). Medium- to large-sized public hospitals in the north of the country were mostly responsible for the reduction in cases (p = 0.0153). CONCLUSIONS: Case reduction was observed at hospitals that have mostly been involved in the treatment of COVID-19 and in the north of the country, the region worst-hit by the pandemic. Similar to other studies, our TAT decreased, even with a similar number of routine cases. Thus, we conclude that it is possible to successfully adapt the workflow of a molecular pathology laboratory to new safety standards without losing efficiency.


Assuntos
Infecções por Coronavirus/epidemiologia , Oncologia , Técnicas de Diagnóstico Molecular , Patologia Molecular , Pneumonia Viral/epidemiologia , Betacoronavirus , COVID-19 , Humanos , Laboratórios , Pessoal de Laboratório , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Programas Nacionais de Saúde , Pandemias , Portugal/epidemiologia , SARS-CoV-2 , Fluxo de Trabalho
9.
J Appl Lab Med ; 5(6): 1307-1312, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: covidwho-696741

RESUMO

BACKGROUND: Numerous nucleic acid amplification assays utilizing different target genes of the SARS-CoV-2 genome have received emergency use authorization (EUA) by the United States Food and Drug Administration (FDA). Limited data are available comparing the test performance characteristics of these assays. METHODS: A diagnostic comparison study was performed to evaluate the performance of the Cepheid Xpert Xpress SARS-CoV-2 assay compared to the Hologic Panther Fusion SARS-CoV-2 assay using clinical nasopharyngeal specimens. Agreement between the two assays was assessed by overall, positive, and negative percent agreement and Cohen's kappa coefficient. RESULTS: A total of 104 (54 positive and 50 negative) clinical nasopharyngeal samples were tested by both assays. Using the Panther Fusion as a reference standard, the Xpert demonstrated an overall agreement of 99.0% [95% confidence interval (CI): 94.8-100], positive percent agreement of 98.1% (95% CI: 90.1-100), and a negative percent agreement of 100% (95% CI: 94.2-100). The kappa coefficient was 0.98 (95% CI: 0.94-1.0). One sample positive by the Panther Fusion with a cycle threshold (Ct) of 38.6 was found to be reproducibly negative by the Xpert assay. CONCLUSIONS: The Cepheid Xpert Xpress SARS-CoV-2 assay provides test performance comparable to the Hologic Panther Fusion SARS-CoV-2 assay while offering laboratories rapid, on-demand testing capacity.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/instrumentação , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/instrumentação , Pneumonia Viral/diagnóstico , RNA Viral/isolamento & purificação , Automação Laboratorial/instrumentação , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Humanos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Reação em Cadeia da Polimerase Multiplex/instrumentação , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Kit de Reagentes para Diagnóstico/estatística & dados numéricos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reprodutibilidade dos Testes , SARS-CoV-2 , Fatores de Tempo , Estados Unidos/epidemiologia
10.
Sci Transl Med ; 12(556)2020 08 12.
Artigo em Inglês | MEDLINE | ID: covidwho-688785

RESUMO

The coronavirus disease 2019 (COVID-19) pandemic caused by the SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) coronavirus is a major public health challenge. Rapid tests for detecting existing SARS-CoV-2 infections and assessing virus spread are critical. Approaches to detect viral RNA based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) have potential as simple, scalable, and broadly applicable testing methods. Compared to RT quantitative polymerase chain reaction (RT-qPCR)-based methods, RT-LAMP assays require incubation at a constant temperature, thus eliminating the need for sophisticated instrumentation. Here, we tested a two-color RT-LAMP assay protocol for detecting SARS-CoV-2 viral RNA using a primer set specific for the N gene. We tested our RT-LAMP assay on surplus RNA samples isolated from 768 pharyngeal swab specimens collected from individuals being tested for COVID-19. We determined the sensitivity and specificity of the RT-LAMP assay for detecting SARS-CoV-2 viral RNA. Compared to an RT-qPCR assay using a sensitive primer set, we found that the RT-LAMP assay reliably detected SARS-CoV-2 RNA with an RT-qPCR cycle threshold (CT) number of up to 30, with a sensitivity of 97.5% and a specificity of 99.7%. We also developed a swab-to-RT-LAMP assay that did not require a prior RNA isolation step, which retained excellent specificity (99.5%) but showed lower sensitivity (86% for CT < 30) than the RT-LAMP assay. In addition, we developed a multiplexed sequencing protocol (LAMP-sequencing) as a diagnostic validation procedure to detect and record the outcome of RT-LAMP reactions.


Assuntos
Betacoronavirus/genética , Betacoronavirus/isolamento & purificação , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/virologia , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Pneumonia Viral/diagnóstico , Pneumonia Viral/virologia , COVID-19 , Colorimetria/métodos , Colorimetria/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , Proteínas do Nucleocapsídeo de Coronavírus , Humanos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Técnicas de Amplificação de Ácido Nucleico/estatística & dados numéricos , Proteínas do Nucleocapsídeo/genética , Pandemias , Fosfoproteínas , Pneumonia Viral/epidemiologia , RNA Viral/genética , RNA Viral/isolamento & purificação , RNA-Seq , SARS-CoV-2 , Sensibilidade e Especificidade , Pesquisa Translacional Biomédica
11.
Biosens Bioelectron ; 167: 112479, 2020 Nov 01.
Artigo em Inglês | MEDLINE | ID: covidwho-684409

RESUMO

COVID-19 pandemic outbreak is the most astounding scene ever experienced in the 21st century. It has been determined to be caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). With the global pandemic, the lack of efficient rapid and accurate molecular diagnostic testing tools has hindered the public opportunely response to the emerging viral threat. Herein, a DNA nanoscaffold hybrid chain reaction (DNHCR)-based nucleic acid assay strategy is reported for rapid detection of SARS-CoV-2 RNA. In this method, the DNA nanoscaffolds have been first constructed by the self-assembly of long DNA strands and self-quenching probes (H1). Then, the SARS-CoV-2 RNA will initiate the hybridization of H1 and free H2 DNA probes along the nanoscaffold, and an illuminated DNA nanostring is instantly obtained. By taking advantages of the localization design of the H1 probes and the temperature tolerance of the isothermal amplification, the proposed DNHCR method can detect target at short responding time (within 10 min) and mild condition (15 °C-35 °C). Moreover, the reliability of DNHCR method in serum and saliva samples have also been validated. Therefore, DNHCR-based method is expected to provide a simple and faster alternative to the traditional SARS-CoV-2 qRT-PCR assay.


Assuntos
Betacoronavirus , Técnicas Biossensoriais/métodos , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/virologia , Pneumonia Viral/diagnóstico , Pneumonia Viral/virologia , Betacoronavirus/genética , Betacoronavirus/isolamento & purificação , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , DNA/síntese química , DNA/química , DNA/genética , Estudos de Viabilidade , Humanos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Nanoestruturas/química , Nanotecnologia , Técnicas de Amplificação de Ácido Nucleico/métodos , Pandemias , Pneumonia Viral/epidemiologia , RNA Viral/análise , RNA Viral/genética , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade
12.
J Clin Microbiol ; 58(9)2020 08 24.
Artigo em Inglês | MEDLINE | ID: covidwho-638997

RESUMO

Analytical sensitivity for SARS-CoV-2 detection is a key performance metric for the evaluation of viral detection assays. We determined analytical limits of detection for seven SARS-CoV-2 assays using serial dilutions of pooled patient material quantified with droplet digital PCR. Limits of detection ranged from ≤10 to 74 copies/ml for commercial high-throughput laboratory analyzers (Roche Cobas, Abbott m2000, and Hologic Panther Fusion) and 167 to 511 copies/ml for sample-to-answer (DiaSorin Simplexa, GenMark ePlex) and point-of-care instruments (Abbott ID NOW). The CDC assay yielded limits of detection ranging from 85 to 499 copies/ml, depending on the extraction method and thermocycler used. These results can help to inform the assay choice for testing approaches to manage the current COVID-19 outbreak.


Assuntos
Betacoronavirus/genética , Técnicas de Laboratório Clínico , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular , Pneumonia Viral/diagnóstico , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Técnicas de Laboratório Clínico/estatística & dados numéricos , Infecções por Coronavirus/epidemiologia , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Pandemias , Pneumonia Viral/epidemiologia , RNA Viral/análise , RNA Viral/genética , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA